FJ6/JTS2D-35(18L) Series Power Distribution Terminal Block (Direct Conductor Connection, Flip-cover) | HAIYAN

FJ6/JTS2D-35(18L) Series Power Distribution Terminal Block (Direct Conductor Connection, Flip-cover)

Product Features

  • Power distribution terminal block with one input and multiple outputs for multi-circuit power and circuit distribution.
  •  Direct conductor connection (screw clamping).
  • Flip-type protective cover design allows convenient opening and closing during wiring.
  • High current-carrying capability for main power infeed/outfeed and heavy-current applications.
  • Suitable for use as a compact busbar solution, heavy-current terminal block, neutral (N) terminal block, protective earth (PE) terminal block, and equipotential bonding terminal block.
  • Reliable screw clamping ensures stable electrical contact.
  • Transparent protective cover for enhanced operational safety.
  • Compact design for DIN rail or panel mounting in control cabinets

Detailed introduction

Application

The FJ6/JTS2D series power distribution terminal blocks are suitable for power and circuit distribution in electrical control equipment, switchgear assemblies,distribution boxes, and multi-circuit enclosures.

They can serve as a compact alternative to small busbars for centralized connection and management of power, neutral, protective earth, and equipotential conductors.

Key Specifications

FJ6/JTS2D-35/2*6(18L)
Configuration: One-input; two-output
Input conductor range: 10-35 mm²
Output conductor range: 1.5–6 mm²
Dimensions: 82(W)*50(H)*18(L)
Order Number: 210705
FJ6/JTS2D-35/4*6(18L)
Configuration: One-input; four-output
Input conductor range: 10-35 mm²
Output conductor range: 1.5–6 mm²
Dimensions: 82(W)*50(H)*18(L)
Order Number: 210706
FJ6/JTS2D-35/6*6(18L)
Configuration: One-input; six-output
Input conductor range: 10-35 mm²
Output conductor range: 1.5–6 mm²
Dimensions: 82(W)*50(H)*18(L)
Order Number: 210707

Installation and Operation

  • Fixed mounting on base plate using M5 screws.
  • DIN rail mounting on standard 35 mm rail (TH-35).

Installation Notes

  • Installation and wiring shall be carried out with the power supply disconnected.
  • During installation and operation, ensure conductors are fully inserted into the clamping area.
  • After installation, all connection points shall be checked for secure fixing

Outline and Mounting Dimension

Reference Table for Copper Conductors for Incoming and Outgoing Lines

Get a Quote