FJ6/JTS2D-50B(29L) Series Power Distribution Terminal Block (Cable Lug/Busbar Connection, Flip-cover) | HAIYAN

FJ6/JTS2D-50B(29L) Series Power Distribution Terminal Block (Cable Lug/Busbar Connection, Flip-cover)

Product Features

  • Power distribution terminal block with one input and multiple outputs for multi-circuit power and circuit distribution.
  • Supports multiple line-in connection methods:

-Cable lug connection

–Copper busbar connection.

  • Flip-type protective cover design allows convenient opening and closing during wiring.
  • High current-carrying capability for main power infeed/outfeed and heavy-current applications.
  • Suitable for use as a compact busbar solution, heavy-current terminal block, neutral (N) terminal block, protective earth (PE) terminal block, and equipotential bonding terminal block.
  • Reliable screw clamping ensures stable electrical contact.
  • Transparent protective cover for enhanced operational safety.
  • Compact design for DIN rail or panel mounting in control cabinets

Detailed introduction

Application

The FJ6/JTS2D-B series power distribution terminal blocks are suitable for power and circuit distribution in electrical control equipment, switchgear assemblies,distribution boxes, and multi-circuit enclosures.

They can serve as a compact alternative to small busbars for centralized connection and management of power, neutral, protective earth, and equipotential conductors.

 

Key Specifications

FJ6/JTS2D-50B/6*16(29L)
Configuration: One-input; six-output
Input conductor range: 25-50 mm²
Output conductor range: 2.5-16 mm²
Dimensions: 82(W)*50(H)*29(L)
Order Number: 210744
FJ6/JTS2D-50B/9*10(29L)
Configuration: One-input; nine-output
Input conductor range: 25-50 mm²
Output conductor range: 2.5-16 mm²
Dimensions: 82(W)*50(H)*29(L)
Order Number: 210745

Installation and Operation

  • Fixed mounting on base plate using M5 screws.
  • DIN rail mounting on standard 35 mm rail (TH-35).

Installation Notes

  • Installation and wiring shall be carried out with the power supply disconnected.
  • During installation and operation, ensure conductors are fully inserted into the clamping area.
  • When using cable lugs or copper busbars for line-in connection, ensure clean and flatcontact surfaces.
  • After installation, all connection points shall be checked for secure fixing

Outline and Mounting Dimension

Reference Table for Copper Conductors for Incoming and Outgoing Lines