FJ6/HYD Series Earthing Type Insulation Piercing Connector(1kV) | HAIYAN

FJ6/HYD Series Earthing Type Insulation Piercing Connector(1kV)

Typical applications include:

  • Protective earthing of overhead insulated conductors
  • Building earthing and equipotential bonding connections
  • Earthing for street lighting poles and distribution pillars
  • Earthing of high-rise building riser cables and outdoor feeder systems

Product Features:

  • No-strip installation using torque nuts to ensure controlled piercing pressure and reliable earthing connection.
  • Low contact resistance and minimal temperature rise, maintaining stable long-term electrical continuity in the earthing circuit.
  • Fully sealed, high-insulation design filled with insulating grease to enhance dielectric strength and environmental protection.
  • Wide applicability for copper, aluminum, and steel-aluminum conductors in 1 kV distribution networks, supporting equipotential bonding and protective earthing functions.

Detailed introduction

Application

The FJ6/HYD series earthing type insulation piercing connector is used for establishing protective earthing and equipotential bonding in 1 kV overhead insulated distribution systems.

It provides a reliable earthing path by connecting insulated conductors to the earthing network, ensuring the safety and continuity of low-voltage distribution circuits.

Key Specifications

FJ6/HYD1-95/25
Applicable Voltage:  1 kV
Applicable lead: 25-95 mm²
Nominal Current:  257 A
Overall Dimensions:  A152*B106*H87
Bolt Quantity:  2 pcs
Order Number:  212563
FJ6/HYD1-120/35
Applicable Voltage:  1 kV
Applicable lead: 35-120 mm²
Nominal Current:  299 A
Overall Dimensions:  A152*B106*H87
Bolt Quantity:  2 pcs
Order Number:  212564
FJ6/HYD1-95/25
Applicable Voltage:  1 kV
Applicable lead: 25-95 mm²
Nominal Current:  257 A
Overall Dimensions:  A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212565
FJ6/HYD1-120/35
Applicable Voltage:  1 kV
Applicable lead: 35-120 mm²
Nominal Current:  299 A
Overall Dimensions: A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212566
FJ6/HYD1-185/95
Applicable Voltage:  1 kV
Applicable lead: 95-185 mm²
Nominal Current:  470 A
Overall Dimensions:  A152*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212567
FJ6/HYD1-240/150
Applicable Voltage:  1 kV
Applicable lead: 150-240 mm²
Nominal Current:  476 A
Overall Dimensions:  A160*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212568

Installation and Operation

  • Install and secure the main insulated conductor at the designated earthing position.
  • Remove approx. 0.6 m of the outer sheath without damaging the phase insulation of the main conductor.
  • Prepare the earthing conductor to the required length and strip the insulation at the connecting end.
  • Insert the earthing conductor fully into the connector’s earthing port to ensure proper engagement with the internal sealing element.
  • Position the connector on the exposed section of the main conductor and tighten the torque nut(s) by hand.
  • Continue tightening with a socket wrench until the preset torque nut(s) break off, indicating that the required installation torque has been achieved and the connection is correctly completed.

Installation Guide