FJ6/TTD 80 Series Multi-branch Type Insulation Piercing Connector (1 KV) | HAIYAN

FJ6/TTD 80 Series Multi-branch Type Insulation Piercing Connector (1 kV)

Typical applications include:

  • LV building distribution networks
  • LV overhead insulated conductor systems
  • Residential and commercial service-entry branching
  • Street-lighting distribution feeders
  • Multi-output LV installations requiring compact connection solutions

Product Features:

  • Multi-branch capability supporting up to four insulated branch conductors for decentralized LV distribution.
  • No-strip installation using shear-head bolts ensures controlled piercing pressure and reliable electrical contact without removing insulation or cutting the main cable.
  • High-strength insulating body resists mechanical stress, vibration, UV exposure, and climatic aging.
  • Low contact resistance and minimal temperature rise ensure stable electrical performance across all branch outputs.
  • Waterproof construction withstands 6 kV under submerged conditions with no breakdown.
  • Corrosion-resistant bolts and hardware ensure durable outdoor performance.
  • Optional waterproof branch caps prevent moisture ingress into unused branch ports.

Detailed introduction

Application

The FJ6/TTD 80 Series multi-branch insulation piercing connectors are used for the connection and branching of LV insulated conductors, providing up to four independent branch outputs from a single main conductor.

They are suitable for LV overhead insulated cable networks, building distribution systems, service-entry connections, and street-lighting distribution circuits.

Key Specifications

ModelNumber of Branch

Outputs(mm²)

Main Conductor

Range (Input)mm²

Branch Conductor

Range (Output)mm²

 Order Number:
FJ6/TTDE 80 F116-95(1.5)2.5-6212669
FJ6/TTDE 82 F110-54(2.5)6-35212670
FJ6/TTDE 83 F110-546-35212671
FJ6/TT1D 82 F125-95(2.5)6-35212672
FJ6/TT2D 82 F225-952×(2.5)6-35212673
FJ6/TT4D 82 F425-954×(2.5)6-35(aluminum)/25(copper)212674
FJ6/TT1D 83 F2125-956-35212675
FJ6/TT2D 83 F3225-952×6-35212676
FJ6/TT4D 83 F5425-954×6-35(aluminum)/25(copper)212677
FJ6/TTDR 82 F2125-9525-70212678
FJ6/TT1D 86 F150-150(2.5)6-35212679
FJ6/TT2D 86 F250-1502×(2.5)6-35212680
FJ6/TT4D 86 F450-1504×(2.5)6-35(aluminum)/25(copper)212681
FJ6/TT1D 87 F2150-1506-35212682
FJ6/TT2D 87 F3250-1502×6-35212683
FJ6/TT4D 87 F5450-1504×6-35(aluminum)/25(copper)212684
FJ6/TTDR 86 F2150-15025-95212685
FJ6/TTDR 86-1 F2150-15025-95212686
FJ6/TTDR 88 F2150-15050-150212687

Installation and Operation

  • Install and secure the main insulated conductor using standard methods.
  • Position the connector at the required branching point and hand-tighten to secure it.
  • Insert each branch conductor fully into the designated branch port; install waterproof caps on unused outlets.
  • Tighten the shear-head bolts using a socket wrench; for multi-bolt models, tighten alternately.
  • Continue tightening until the shear-head breaks off, indicating correct torque has been achieved.
  • Support the connector body with a secondary wrench during tightening to reduce conductor stress.