FJ6/HYD10 Series Earthing Type Insulation Piercing Connector(10kV) | HAIYAN

FJ6/HYD10 Series Earthing Type Insulation Piercing Connector(10kV)

Typical applications include:

  • Protective earthing of 10 kV overhead insulated conductors.
  • Earthing and equipotential bonding in medium-voltage distribution networks.
  • Earthing for pole-mounted transformers and distribution pillars.
  • Earthing of outdoor MV feeder systems and industrial distribution lines.

Product Features

  • No-strip installation using turque nuts for controlled piercing pressure and reliable earthing connection.
  • Low contact resistance and low temperature rise, ensuring stable electrical performance under 10 kV operating conditions.
  • Fully sealed, high-insulation design filled with insulating grease to improve dielectric strength and outdoor reliability.
  • Wide applicability for copper, aluminum, and steel-aluminum conductors used in 10 kV overhead distribution systems.

Detailed introduction

Application

The FJ6/HYD10 series earthing type insulation piercing connectors are used for establishing protective earthing and equipotential bonding in 10 kV overhead insulated distribution systems.

They provide a reliable earthing path by connecting insulated conductors to the earthing network, ensuring the safety and continuity of medium-voltage distribution circuits.

Key Specifications

FJ6/HYD10-95/25
Applicable Voltage:  10 kV
Applicable lead: 25-95 mm²
Nominal Current:  257 A
Overall Dimensions:  A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212576
FJ6/HYD10-120/35
Applicable Voltage:  10 kV
Applicable lead: 35-120 mm²
Nominal Current:  299 A
Overall Dimensions: A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212577
FJ6/HYD10-185/95
Applicable Voltage:  1 0kV
Applicable lead: 95-185 mm²
Nominal Current:  470 A
Overall Dimensions:  A152*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212578
FJ6/HYD10-240/150
Applicable Voltage:  10 kV
Applicable lead: 150-240 mm²
Nominal Current:  476 A
Overall Dimensions:  A160*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212579

Installation and Operation

  • Remove the required length of the outer sheath at the earthing position without damaging the insulation layer.
  • Prepare the earthing conductor to the required length and strip the insulation at the connection end.
  • Insert the earthing conductor fully into the earthing port to ensure proper engagement with the internal sealing element.
  • Position the earthing connector on the exposed section of the main conductor and hand-tighten the torque nut(s).
  • Tighten the torque nut(s) with a socket wrench until the preset torque nuts break off, indicating that correct installation torque has been achieved.