FJ6/HYD Series Branch Type Insulation Piercing Connector — Flame-retardant Version(10kV) | HAIYAN

FJ6/HYD Series Branch Type Insulation Piercing Connector — Flame-retardant Version(10kV)

product features

  • Optional flame-retardant version available for ZR/NH cables requiring higher fire-safety performance.
  • All components are flame-retardant and compliant with 960°C glow-wire and vertical burning tests.
  • Connector body made of high-strength, flame-retardant insulating material resistant to mechanical and climatic stress.
  • Waterproof construction tested under submerged conditions to ensure insulation integrity in MV applications.
  • Sealed branch end-cap prevents moisture ingress.
  • Suitable for live-line or de-energized installation.

Detailed introduction

Flame-retardant Version Features

  • Optional flame-retardant version available for ZR/NH cables requiring higher fire-safety performance.
  • All components are flame-retardant and compliant with 960°C glow-wire and vertical burning tests.
  • Connector body made of high-strength, flame-retardant insulating material resistant to mechanical and climatic stress.
  • Waterproof construction tested under submerged conditions to ensure insulation integrity in MV applications.
  • Sealed branch end-cap prevents moisture ingress. • Suitable for live-line or de-energized installation.

Application

The FJ6/HYD10 series earthing type insulation piercing connectors are used for establishing protective earthing and equipotential bonding in 10 kV overhead insulated distribution systems.

They provide a reliable earthing path by connecting insulated conductors to the earthing network, ensuring the safety and continuity of medium-voltage distribution circuits.

Key Specifications

FJ6/HYD10/V0-95/25
Applicable Voltage:  10 kV
Applicable lead: 25-95 mm²
Nominal Current:  257 A
Overall Dimensions:  A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212610
FJ6/HYD10/V0-120/35
Applicable Voltage:  10 kV
Applicable lead: 35-120 mm²
Nominal Current:  299 A
Overall Dimensions: A145*B140*H95
Bolt Quantity:  2 pcs
Order Number:  212611
FJ6/HYD10/V0-185/95
Applicable Voltage:  1 0kV
Applicable lead: 95-185 mm²
Nominal Current:  470 A
Overall Dimensions:  A152*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212612
FJ6/HYD10/V0-240/150
Applicable Voltage:  10 kV
Applicable lead: 150-240 mm²
Nominal Current:  476 A
Overall Dimensions:  A160*B140*H113
Bolt Quantity:  2 pcs
Order Number:  212613

Installation and Operation

  • Install and secure the medium-voltage insulated conductor using standard methods.
  • Remove the required length of the outer sheath at the earthing position without damaging the insulation layer.
  • Prepare the earthing conductor of the required length and strip the sheath at the connection end.
  • Position the earthing connector on the exposed section and tighten the shear-head bolts until they shear off.