FJ6/HYC10 Series Branch Type Insulation Piercing Connector(10kV) | HAIYAN

FJ6/HYC10 Series Branch Type Insulation Piercing Connector(10kV)

Typical applications include:

  • 10 kV overhead distribution feeders.
  • Medium-voltage branching and network expansion.
  • Pole-mounted transformer connections.
  • Rural and urban MV distribution systems.
  • Industrial outdoor insulated conductor feeders.

Product Features

  • No-strip installation using torque nuts for controlled piercing pressure.
  • Low contact resistance and low temperature rise, ensuring stable electrical performance under MV operating conditions.
  • Fully sealed, high-insulation design filled with insulating grease to improve dielectric strength and outdoor reliability.
  • Wide applicability for steel-aluminum, copper, and aluminum conductors, including different- and equal-diameter branching or jointing.

Detailed introduction

Application

The FJ6/HYC10 series branch type insulation piercing connectors are used for the connection and branching of overhead insulated conductors in medium-voltage distribution networks.

They are suitable for 10 kV insulated lines, providing reliable electrical performance for branching, tapping, and line extensions in MV overhead systems.

Key Specifications

FJ6/HYC10-95/70
Applicable Voltage: 10 kV
Main Conductor Range (Input): 25–95 mm²
Branch Conductor Range (Output):16–70 mm²
Nominal Current: 207A
Overall Dimensions: A68 × B82.5 × H108 mm
Bolt Quantity: 2 pcs
Order Number: 212569
FJ6/HYC10-150/150
Applicable Voltage: 10 kV
Main Conductor Range (Input): 35–150 mm²
Branch Conductor Range (Output):35–150 mm²
Nominal Current: 342A
Overall Dimensions: A59.5 × B68 × H93 mm
Bolt Quantity: 2 pcs
Order Number: 212570
FJ6/HYC10-185/185
Applicable Voltage: 10 kV
Main Conductor Range (Input): 95-185 mm²
Branch Conductor Range (Output):16–50 mm²
Nominal Current: 162A
Overall Dimensions: A78.5 × B80 × H113 mm
Bolt Quantity: 2 pcs
Order Number: 212571
FJ6/HYC10-185/95
Applicable Voltage: 10 kV
Main Conductor Range (Input): 70-185 mm²
Branch Conductor Range (Output):16–95 mm²
Nominal Current: 257A
Overall Dimensions: A78.5 × B80 × H113 mm
Bolt Quantity: 2 pcs
Order Number: 212572
FJ6/HYC10-240/150
Applicable Voltage: 10 kV
Main Conductor Range (Input): 95-240 mm²
Branch Conductor Range (Output):50–70 mm²
Nominal Current: 342A
Overall Dimensions: A84 × B83 × H113 mm
Bolt Quantity: 2 pcs
Order Number: 2125673
FJ6/HYC10-240/185
Applicable Voltage: 10 kV
Main Conductor Range (Input): 95-240 mm²
Branch Conductor Range (Output):70-185 mm²
Nominal Current: 399A
Overall Dimensions: A84 × B83 × H113 mm
Bolt Quantity: 2 pcs
Order Number: 212574
FJ6/HYC10-240/240
Applicable Voltage: 10 kV
Main Conductor Range (Input): 95-240 mm²
Branch Conductor Range (Output): 95-240 mm²
Nominal Current: 476A
Overall Dimensions: A89 × B85.5 × H113 mm
Bolt Quantity: 2 pcs
Order Number: 212575

Installation and Operation

  • Install and secure the medium-voltage insulated conductor using standard methods.
  • Remove the required length of outer sheath at the branching position without damaging the insulation layer.
  • Prepare the branch conductor and strip the insulation at both ends as required for MV installations.
  • Position the connector on the exposed section and hand-tighten the torque nut(s).
  • Tighten the torque nut(s) with a socket wrench until the preset torque nuts break off, indicating correct installation torque has been achieved.